Tabreed SBS cooling pads consist of corrugated sheets of cellulose gathered in an opposite sequence with a ''bee-hive'' structure which generates air flow inside the cell.

  • This sheets have a very high ability in absorbing water and they are chemically treated with an odorless substance to prevent disintegration and to achieve exceptional wetting properties, air flow, high efficiency and maximum durability. This way a high absorption capacity can be guaranteed especially given the strong and tough structure of the cell pads.
  • The forms and inclinations of the formed flutes have been designed to obtain high air saturation, effiency and drop for the different applications and conditions.
  • Tabreed SBS provides flexibility in producing different heights and angle sizes as per customer's request.
  • Tabreed SBS distributor ''Bee-hive'' design ensures a uniform air distribution all over the cooling area.
  • Tabreed SBS packaging has been designed in a way that facilities handling and loading of trucks or containers.
  • Tabreed SBS packaging has been designed in a way that facilities handling and loading of trucks or containers.

Product Specifications

Tabreed SBS is available in different heights and thickness as indicated in a table. The product dimensions describes the characteristics of the cell pad, here below are the different angles, corrugations and the flute heights.

Height Width Thickness Angles Corrugation Height
100 60 10 45x45 - 30x60 5 & 7
100 60 15 45x45 - 30x60 5 & 7
120 60 10 45x45 - 30x60 5 & 7
120 60 15 45x45 - 30x60 5 & 7
150 60 10 45x45 - 30x60 5 & 7
150 60 15 45x45 - 30x60 5 & 7
180 60 10 45x45 - 30x60 5 & 7
180 60 15 45x45 - 30x60 5 & 7
200 60 10 45x45 - 30x60 5 & 7
200 60 15 45x45 - 30x60 5 & 7

Tabreed SBS Axial Fans

1380 * 1380 * 400 mm Tabreed SBS Fan
Motor Self-produced,stable quality,%100 copper
Blade Size 1.250mm
Blade Material Stainless Steel
Blade RPM 439 r/min.
Frame Material Galvanized
Shutter Material Galvanized
Air Flow 45.000 m3/h.
Power 1.100 w.
Shutter Open Type Two hummers on two side corners push
Weight 55 kg.
1380 * 1380 * 450 mm Tabreed SBS Fan
Motor Self-produced,stable quality,%100 copper, with cooling fan
Blade Size 1.250mm
Blade Material Stainless Steel
Blade RPM 439 r/min.
Frame Material Galvanized
Shutter Material Galvanized
Air Flow 45.000 m3/h.
Power 1.100 w.
Shutter Open Type Push and pull device which connect fan blade
Weight 75 kg.

Applications

Poultry Houses

Poultry Houses

Since that most poultry houses with tunnel ventilations are not sufficient to derive the genetic growth potential from the chicks. Tabreed SBS cooling pads and system isconsidered a very important ingredient in combining the tunnel ventilation property of the poultry houses to provide the chicks with the optimum environmental conditions required for their healty growth.

The highest levels of performance from fully feathered broilers can be obtained in still-air temperatures below 26 degrees celcius. In most poultry houses, the still air temperatures can range from 19-26 degrees celcius, if temperature exceeds this range, its known that it can distort the growth potential of those broilers.

Work Places,Factories and Warehouses

Work Places,Factories and Warehouses

Tabreed SBS also works in factories and work places to provide a ventilated working environment for workers in order to overcome the heat that is radiated from the machinery. Which helps in raising the effiency of the workers and hence increase productivity.

Cooling Towers

Tabreed SBS can also be applied in cooling towers and industrial chillers used in factories. The cell pads are considered as a more cost-effective alternative than the metal sheets currently being used in industrial chillers.

Live Stock

Live Stock

High temperatures can have a direct negative impact on birds and animal performance in terms of their growth, production and metabolism, in addition to their ability to convert feed to useful products.

Green Houses

Green Houses

Countries with rough climates can have an atmospheric temperature of 37 degrees celcius or sometimes even above, this always poses negative implications on the growth rates of crops inside the green houses, encouraging endothermic chemical reactions by the plant that distorts their growth rates.

Ventilations systems centralized cooling and heating systems in addition to supplemental lighting have contributed to extend the applications of green houses to year round cropping on relatively larger scales.

Cooling of green houses is necessary to maintain a temperature that shouldn't exceed 24 degrees celcius for the healty growth of crops. High temperatures are known to cause loss of strengt, reduction of flower size and delay of crop flowering. Tabreed SBS cooling pads helps to maintain a high relative humidity at a constant temperature, which doesn't fluctuate during day light. Hence endorsing the healty growth of crops.

Maintenance

Disintegration of the cell pads can be minimized by maintaining a continuous ''bleed-off'' or by periodically filing the stump. Tabreed SBS can assist you by recommending indivual ''bleed-of'' rates. In that case fractional timers shouldn't be used, as they do not enhance the performance of the cooling pads and they contribute to the development of scales which result in reducing the air flow.

If algae are allowed to grow on Tabreed cell pads, it may eventually block the flutes and prohibit the air flow from entering inside the cell pads. This leads to an increase in static pressure and reduces the performance and effiency of the cell pads. The growth of the algae can be controlled or reduced by either early maintenance techniques or by applying black coated polishing to the cell pads. Chlorine or bromine shouldn't be used on the cell pads as a means of preventing the growth of the algae.

Performance

Tabreed SBS 45/45 Angle: This product is suitable for application where a good combination between humidification, efficiency and pressure drop is required.

Tabreed SBS 30/60 Angle: This product is ideal for air conditioning applications, where air velocities are greater, since it has been designed to avoid the release of water droplets(from the outlet side). Whilst maintaining good effiencies and adequate pressure drops.